Skip to main content
background

PREMIUM PYE G200 S40

Heat weldable underlayer bituminous felt

Application:

  • Underlayer in multi-layer roof coverings, terraces and balconies, for any type of substrate
  • Dedicated especially for use on thermal insulation layers
  • Waterproofing layer on ballasted roofs and under pavements intended for traffic
  • Waterproofing for underground parts of buildings

Properties:

  • Resistant to punctures and heavy loads
  • Double SBS modification
  • For use in reduced ambient temperatures
  • Protects against radon penetration
  • Fixed by welding and mechanically

Available packaging:

  • 5 m

Type of reinforcement

glass fabric

Top finishing

fine-grained

Low temperature flexibility

≤ -20°C

Width

≥ 0,99 m

Straightforwardness

≤ 10 mm per 5 m of roll length

Thickness

(4,0 ± 0,2) mm

Resistance to external fire exposure*
*applies to the examined layer systems

Broof(t1), Broof(t2)

Reaction to fire

class E

Watertightness:
waterproof at a pressure


≥ 2 kPa (metoda A)
≥ 10 kPa (metoda A)
≥ 60 kPa (metoda B)
≥ 200 kPa (metoda B)

Maximum tensile force:
- longitudinal
  extension
- transversal
  extension


1500 ± 500 N/50 mm
(12 ± 7) %
2900 ± 900 N/50 mm
(12 ± 7) %

Reference document(s)

EN 13707:2004+A2:2009;
EN 13969:2004;
EN 13969:2004/A1:2006;
EN 13970:2004;
EN 13970:2004/A1:2006

Resistance to root penetration

NPD

Resistance to static loading


≥ 5 kg (metoda A)
≥ 5 kg (metoda B)

Resistance to impact

≥ 1750 mm (metoda A)

Resistance to tearing:
- longitudinal
- transversal


600 ± 300 N
400 ± 200 N

Resistance of the joint:
- shear strength
• longitudinal joint
• transversal joint


1800 ± 700 N/50 mm
1500 ± 500 N/50 mm

Permeation of water vapour

2,8E+12 m²·Pa·s/kg ± 25%

Diffusion resistance coefficient Sd

approx. 560 m

Radon diffusion coefficient

D = 3,2 × 10⁻11 ± 1,2 × 10⁻11 m2/s

Durability:
- durability after artificial ageing, watertightness
- durability against chemical
- after artificial ageing, vapour diffusion
- chemicals resistance


≥ 60 kPa (method B)
acc. to annex A of the standard EN 13969
2,8E+12 m²·Pa·s/kg ± 50%
acc. to annex A of the standard EN 13970

  • Making an insulation using bituminous felt should be NEXLER PREMIUM PYE G200 S40 carried out according to the technical design, in accordance with the current building regulations and the detailed guidelines for the design and execution of insulation contained in NEXLER Insulation Systems and the Technical Data Sheet.
    The bituminous felt should be installed in ambient temperatures of above 0°C, this requirement applies to the time of day and night.
    Do not carry out insulation work during strong winds and precipitation.

See also

BITFLEX Primer 8 kg 320x320

BITFLEX Primer

Quick-drying bituminous and anionic primer (concentrate)

Find out more SYSTEM
Bitumy rozpuszczalnikowe - Penetrator g7 320x320

Penetrator G7

Quick-drying primer modified with SBS for under bituminous felt

Find out more SYSTEM
320x320pc_Premium FF_PJ FF_Ultimax FF.webp

PREMIUM PYE PV200 S30 FF