Skip to main content
background

Plan PYE G200 S30 SP

Self-adhesive underlayer bituminous felt

Application:

  • Underlayer in multi-layer roof coverings, terraces and balconies, for any type of substrate
  • Particularly recommended for thermal insulation layers made of EPS
  • Damp-proof insulation of underground parts of building
  • Effective vapor barrier layer
  • Waterproofing layer on ballasted roofs and under pavements intended for traffic

Properties:

  • Double SBS modification
  • Excellent self-adhesive properties
  • Durable and puncture-resistant
  • Easy and convenient for roof detail work
  • Self-adhesive and mechanical installation

Available packaging:

  • 10 m

Type of reinforcement

glass fabric

Coating on the top side

foil

Low temperature flexibility

≤ -20°C

Width

≥ 0,99 m

Straightforwardness

≤ 20 mm per 10 m roll length

Thickness

(3,0 ± 0,2) mm

Resistance to external fire exposure*
*applies to the examined layer systems

Broof(t1)

Reaction to fire

class E

Watertightness:
waterproof at a pressure


≥ 2 kPa (method A)
≥ 10 kPa (method A)
≥ 200 kPa (method B)

Maximum tensile force:
- longitudinal
  extension
- transversal
  extension


1500 ± 500 N/50 mm
(12 ± 7) %
2900 ± 900 N/50 mm
(12 ± 7) %

Resistance to root penetration

NPD

Resistance to static loading

≥ 5 kg (method B)

Resistance to impact

≥ 1000 mm (method A)

Resistance to tearing:
- longitudinal
- transversal


650 ± 350 N
650 ± 350 N

Resistance of the joint:
- shear strength
• longitudinal joint
• transversal joint



1800 ± 700 N/50 mm
1500 ± 500 N/50 mm

Permeation of water vapour

2,0E+12 m²·Pa·s/kg ± 25%

Diffusion resistance coefficient Sd

approx. 400 m

Durability:
- durability after artificial ageing, watertightness
- durability against chemical
- after artificial ageing, vapour diffusion
- chemicals resistance


≥ 2 kPa (method A)
acc. to annex A of the standard EN 13969
2,0E+12 m²·Pa·s/kg ± 50%
acc. to annex A of the standard EN 13970

Reference document(s)

EN 13707:2004+A2:2009;
EN 13969:2004;
EN 13969:2004/A1:2006;
EN 13970:2004;
EN 13970:2004/A1:2006

  • Making an insulation using NEXLER Plan PYE G200 S30 SP bituminous felt should be carried out according to the technical design, in accordance with the current building regulations and the detailed guidelines for the design and execution of insulation contained in NEXLER Insulation Systems and the Technical Data Sheet.
    The bituminous felt should be installed in ambient temperatures of above +10°C, this requirement applies to the time of day and night.
    Do not carry out insulation work during strong winds and precipitation.

See also

BITFLEX Primer 8 kg 320x320

BITFLEX Primer

Quick-drying bituminous and anionic primer (concentrate)

Find out more SYSTEM
Bitumy rozpuszczalnikowe - Penetrator g7 320x320

Penetrator G7

Quick-drying primer modified with SBS for under bituminous felt

Find out more SYSTEM
Papy specjalne - Stick 320x320

Stick

Self-adhesive underlayer bituminous felt

Find out more SIMILAR
Papy specjalne - Alu aquastoper 320 x 320

Alu Aquastoper SP

Self-adhesive vapour barrier bituminous felt

Find out more SIMILAR

Documents for download

icon Declaration of Performance

Search for a document

Archival documents

Type of document
Year
Month