Skip to main content
background

Superdach 20

Single-layer bituminous felt

Application:

  • Single-layer covering for pitched roofs
  • For new and renovated roofs

Properties:

  • Durable, flexible and puncture-resistant
  • Fixed mechanically
  • Lightweight and easy to transport and installation
  • Available in colors: red, graphite

Available packaging:

  • 10 m

Type of reinforcement

non-woven polyester reinforced with glass fibers

Top finishing

coarse grained

Low temperature flexibility

≤ -20°C

Width

≥ 0,99 m

Straightforwardness

≤ 20 mm per 10 m roll length

Thickness

(2,6 ± 0,3) mm

Resistance to external fire exposure*
*applies to the examined layer systems

Broof(t1)

Reaction to fire

class E

Watertightness:
waterproof at a pressure


≥ 10 kPa (method A)

Maximum tensile force:
- longitudinal
  extension
- transversal
  extension


600 ± 200 N/50 mm
(45 ± 15) %
400 ± 200 N/50 mm
(45 ± 15) %

Resistance to static loading

≥ 5 kg (method A)

Resistance to impact

≥ 250 mm (method A)

Resistance to tearing:
- longitudinal
- transversal


200 ± 100 N
200 ± 100 N

Resistance of the joint :
- shear strength 
  • longitudinal joint 
  • transversal joint
- tear off strength
  • longitudinal joint
  • transversal joint



250 ± 150 N/50 mm
500 ± 200 N/50 mm

60 ± 50 N/50 mm
60 ± 50 N/50 mm

Dimensional stability

≤ 0,5%

Durability: flow resistance at elevated temperature

(100 ± 10)°C

Reference document(s)

EN 13707:2004+A2:2009
  • Making an insulation using NEXLER Superdach 20 bituminous felt should be carried out according to the technical design, in accordance with the current building regulations and the detailed guidelines for the design and execution of insulation contained in NEXLER Insulation Systems and the Technical Data Sheet.
    The bituminous felt can be used in moderately sub-zero temperatures (down to -5°C) in dry weather, and an adhesive of suitable temperature and consistency should be used to bond the cross overlaps.
    Do not carry out insulation work during strong winds and precipitation.

Get more details

No image available

NEXLER Superdach 20 – quick and easy covering for wooden pitched roofs!

Good weather is conducive to outdoor works, especially when it comes to building or modernising light structures such as gazebos, sheds and summer houses.

No image available

Pitched Roof Waterproofing: The Professional and DIYer's Guide to a Watertight Roof

Pitched Roof Waterproofing: The Professional and DIYer's Guide to a Watertight Roof

See also

klej_do_pap_i_gontow_320x320pc

Adhesive for Bituminous Felts and Shingles

Bituminous roofing adhesive

Find out more SYSTEM
2400x2400pc_Arbolex_Aqua_Stop_10kg

Arbolex Aqua Stop

Roofing putty for repairs and seals

Find out more SYSTEM
Papy specjalne - Optimax pv 320x320

Optimax PV

Bituminous membrane for pitched roofs

Find out more SIMILAR

Documents for download

icon Declaration of Performance

icon Technical Data Sheet

Search for a document

Archival documents

Type of document
Year
Month