EPOLIS EP 603 VERTICAL
Epoxy sealant
Application:
- For filling expansion joints with a width from 5 to 35 mm on vertical surfaces (NEXLER EPOLIS EP 603 Vertical version) and horizontal surfaces (NEXLER EPOLIS EP 603 Horizontal version) inside and outside buildings
- For closing scratches and cracks on vertical
- For closing scratches and cracks on horizontal surfaces, also with a vehicular traffic load
Properties:
- Very good adhesion to substrates made of concrete, ceramic cladding and resin flooring
- Creates a coating resistant to mechanical stress (abrasion, impact)
- Resistant to acidic or alkaline chemical media
- Resistant to water and marine and industrial atmospheres
- Resistant to impact of domestic wastewater (wastewater treatment plants)
Available packaging:
- 2 kg
Composition |
|
Colors | light grey 7040 |
Density |
|
Mixing ratio |
|
Open time | 45 mins |
Initial drying time | approx. 6 h (skinning) |
Full curing time | 7 days |
Pedestrian traffic load | after 24 h |
Elastic recovery | ≥ 40% |
Tensile properties at maintained extension | no failure |
Adhesion/cohesion properties at variable temperatures | no failure |
Adhesion/cohesion properties at maintained extension after water immersion | no failure |
Loss of volume | ≤ 25% |
Resistance to flow | ≤ 3 mm |
Breaking load | approx. 350 N |
Elongation at break | ≥ 60% |
Amplitude | ± 12,5% |
Application temperature | from +15°C to +30°C |
Relative air humidity | max. 70% |
Reference document(s) | PN-EN ISO 11600:2004; |
The works should be carried out at an ambient temperature of +15°C to +30°C, with a maximum relative humidity of 70%. Higher temperatures and humidity accelerate the setting time of the mix. At lower temperatures, a delay in setting is to be expected, as well as a change in the consistency of the material and as a result of that an increase in consumption. The temperature of the substrate must always be at least 3°C above the dew point temperature until the material is fully cured.
Works should not be carried out during precipitation and strong sunlight.
The premises where the work takes place must be sectioned off, protected from unauthorised access and a safety zone must be maintained against the use of open flames, particularly before conducting welding work. During the works, very good ventilation of the work area should be ensured.
- gap dimension 5 x 5 mm - approx. 0,035 kg/lm
- gap dimension 6 x 6 mm - approx. 0,05 kg/lm
- gap dimension 8 x 8 mm - approx. 0,09 kg/lm
- gap dimension 10 x 10 mm - approx. 0,14 kg/lm
- gap dimension 12 x 12 mm - approx. 0,225 kg/lm
- gap dimension15 x 8 mm - approx. 0,30 kg/lm
- gap dimension 20 x 10 mm - approx. 0,35 kg/lm
- gap dimension 25 x 12 mm - approx. 0,40 kg/lm
- gap dimension 30 x 15 mm - approx. 0,54 kg/lm